Ful­ly auto­ma­tic cross-flow mem­bra­ne fil­tra­ti­on system with unfil­tra­te and fil­tra­te buf­fer tanks. In addi­ti­on, our scope of deli­very com­pri­sed the soft­ware deve­lo­p­ment for an upstream blen­ding system and a down­stream mul­ti­mi­xer system with a coo­ler sup­plied by the Cen­tec company.

Customer

Bucher Unipek­tin AG

Plant type

Fruit juice

Project execution

2019

Project scope

  • 720data points
  • 3 MCC
  • 2 PCC

Our services

  • Con­cept design and consulting
  • Elec­tri­cal engineering
  • Pro­gramming of Allen Bradley
  • Panel­View visualisation
  • Inte­gra­ti­on in Thatcher’s network
  • Switch­gear and con­trol system
  • Elec­tri­cal installation
  • Elec­tri­cal instal­la­ti­on supervision
  • Signal test and start-up

Technology applied

  • Allen Brad­ley Point I/O
  • PLC Con­trolLogix
  • Touch Panel Win­dows CE 6.0
  • EPlan P8

Contact

Karl Zol­ler, Seni­or Pro­cess Auto­ma­ti­on Con­sul­tant, Schmid Auto­ma­ti­on AG